Product Description
- Specifications
- Product Options
- Tech Tips
- Announcements
- Documents
Product specifications for ES-FA-9AA
The ES-FA-9AA specifies: , Safety Relay Module for E-Stop/Rope Pull/Interlock, Supply Voltage: 24 V ac/dc, Safety Input: 1 Dual/Single Channel, Safety Output: 3 NO, 6 Amp; Aux Output: None, Terminal Block: Removable; Width: 22.5mm, Self-Checking Circuitry, Auto/Manual Reset, , Part Number:60131,
Power | - AC/DC Universal |
Device Type | - Safety Relay |
Safety Module Type | - Emergency Stop Module |
Expandable | - No |
LCD Display | - No |
Dimension (H x W x D in mm) | - 84 x 22.5 x 118 |
Relative Humidity | - 90% @ 50° C |
Max Operating Temperature ( °C) | - 50 |
Input Operation | - Simultaneous or Concurrent |
Number of Safe Inputs | - 1 |
Input Configuration | - 2 NC or 1 NC |
Safety Input - Dual Channel (Dry Contact) | - 10-20 mA @ 12 V dc |
Safety Input - Reset | - 20 mA @ 12 V dc (dry contact only) |
Independently Controlled Safe Outputs | - 1 |
Output Configuration | - 3 NO |
Non Safe Output Rating | - N/A |
Safe Output Rating | - Relay - 6 A |
Splittable Safe Output | - No |
Mechanical Life (Operations in Millions) | - 20 |
Power Consumption | - 2 W / 2 VA |
Recovery Time (ms) | - 250 |
Response Time (ms) | - 25 (typical) |
Supply Voltage | - 24 V ac/dc +/- 10% |
Terminal Type | - Screw |
Removable Terminals | - Yes |
Vibration | - 10-55 Hz at 0.35 mm |
Electrical Life (Cycles @ VA) | - 1,000,000 @ 450 VA |
IP Rating | - IP20 |
PL Rating | - e |
Safety Category Rating | - 4 |
SIL Rating | - 3 |
SISTEMA | - PFHd = 5.1 x 10-10 |
Safety Input - Single Channel | - 40-100 mA @ 24 V ac/dc +/- 10% |
Input Resistance | - 100 Ω max. per channel |
E-Stops/Rope Pulls | - Yes |
Safety Mat | - No |
Motor Speed | - No |
Muting | - No |
Gate Switch (NC/NC) Input | - Yes |
Gate Switch (NC/NO) Input | - No |
Gate Switch (OSSD) Input | - No |
Light Curtains/Scanner with EDM Input | - No |
Light Curtains/Scanner without EDM Input | - No |
EtherNet/IP | - No |
Common Ethernet Protocol | - No |
Modbus/TCP | - No |
PCCC | - No |
PROFINET | - No |
In-Series Diagnostics | - No |
Recovery Time | - 250 |