Product specifications for GM-FA-10J
The GM-FA-10J specifies: , Safety Relay Module for Interlocks, Supply Voltage: 24 V ac/dc, Safety Input: Interlocks with complementary contacts, Safety Output: 2 NO, 6 Amp; Aux Output: None, Terminal Block: Removable; Width: 22.5mm, Self-Checking Circuitry, Auto/Manual Reset, , Part Number:60987,
Power | - AC/DC Universal |
Device Type | - Safety Relay |
Safety Module Type | - Gate Monitoring Module |
Expandable | - No |
LCD Display | - No |
Dimension (H x W x D in mm) | - 84 x 22.5 x 118 |
Relative Humidity | - 90% @ 50° C |
Max Operating Temperature ( °C) | - 50 |
Input Operation | - Simultaneous within 3.0 s |
Number of Safe Inputs | - 2 |
Input Configuration | - 1 complementary or 2 x complementary (contact) |
Safety Input - Dual Channel (Dry Contact) | - 20-50 mA @ 15-30 V dc |
Safety Input - Reset | - 20 mA @ 12 V dc (dry contact only) |
Independently Controlled Safe Outputs | - 1 |
Output Configuration | - 2 NO |
Non Safe Output Rating | - N/A |
Safe Output Rating | - Relay - 6 A |
Splittable Safe Output | - No |
Mechanical Life (Operations in Millions) | - 50 |
Power Consumption | - 3 W / 3 VA |
Recovery Time (ms) | - 250 |
Response Time (ms) | - 35 (max.) |
Supply Voltage | - 24 V ac/dc +/- 15% |
Terminal Type | - Screw |
Removable Terminals | - Yes |
Vibration | - 10-55 Hz at 0.35 mm |
Electrical Life (Cycles @ VA) | - 1,000,000 @ 250 VA |
IP Rating | - IP20 |
PL Rating | - e |
Safety Category Rating | - 4 |
SIL Rating | - 3 |
SISTEMA | - PFHd = 1.54 x 10-9 |
Input Resistance | - 270 Ω max. per channel |
E-Stops/Rope Pulls | - Yes |
Safety Mat | - No |
Motor Speed | - No |
Muting | - No |
Gate Switch (NC/NC) Input | - No |
Gate Switch (NC/NO) Input | - Yes |
Gate Switch (OSSD) Input | - No |
Light Curtains/Scanner with EDM Input | - No |
Light Curtains/Scanner without EDM Input | - No |
EtherNet/IP | - No |
Common Ethernet Protocol | - No |
Modbus/TCP | - No |
PCCC | - No |
PROFINET | - No |
In-Series Diagnostics | - No |
Recovery Time | - 250 |