Product Description
- Specifications
- Product Options
- Tech Tips
- Announcements
- Documents
Product specifications for LT3PULV
The LT3PULV specifies: , LT3 Series: Laser Retroreflective Time-of-Flight S, Range: 500 mm to 50 m; 12-24 V dc , Outputs: Discrete: PNPAnalog 0-10V, 2 m (6.5 ft) Cable, , Part Number:67273,
Sensing Beam | - Visible Red Laser |
Max Measurement Range | - >20 m |
Power | - DC |
Cable Length (m) | - 2 |
PC Configurable | - No |
Sensing Mode (General) | - Retroreflective |
Sensing Mode (Detailed) | - Time of Flight |
Housing Style | - Rectangular |
Device Type | - Sensor |
Primary Housing Material | - ABS |
Laser Classification | - Class 1 |
Input/Output | - Analog & Discrete |
Indicator | - LED(s) |
Connection | - Flying Leads |
Analog Output Configuration | - 0-10 V dc |
Quick Disconnect Type | - No QD |
Analog Resolution/Discrete Repeatability | - 5 to 6 at slow response speed |
Max Sensing Distance (mm) | - 50000 |
Minimum Sensing Distance (mm) | - 500 |
Power Supply | - 12-24 V dc |
Delay at Power-up (ms) | - 1000 |
Sensing Beam Wavelength (nm) | - 658 |
Adjustments | - Push Button; Remote Teach |
Temperature Effect (mm/°C) | - 3 mm/°C |
Number of Pins | - 8 |
Output Saturation Voltage PNP Outputs | - < 1.2 V at 10 mA; < 1.6 V at 100 mA |
Analog Voltage Output Rating | - 2.5 kΩ min. load impedance |
Max Discrete (Switched) Output (mA) | - 100 |
Discrete (Switched) Outputs | - 1 PNP |
Output Protection | - Protected against short circuit conditions |
IP Rating | - IP67 |
NEMA Rating | - NEMA 6 |
Max Operating Temperature (°C) | - 50 |
Max Op. Relative Humidity Non-Condensing (%) | - 90 at 50°C |
Window Material | - Acrylic |
Warm-up Time (minutes) | - 30 |
Minimum Response Time (ms) | - 1 |
Spot Size (@ Reference Distance) | - 6 mm |
Analog Linearity (mm) | - +/- 60 mm from 0.5 to 50 m |
Minimum Window Size (mm) | - 40 |
Remote Teach and Laser Control Input Impedence | - 18 kΩ min. (65 kΩ min at 5 V dc) |
Discrete Output Hysteresis (mm) | - 6 |
Laser Control | - Yes |
Max Ambient Light (Lux) | - 5000 |
Max Off-state Leakage Current (µA) | - 5 |
Power/Current Consumption (exclusive of load) | - 108 mA max @ 24 V dc |
Supply Protection Circuitry | - Protected against reverse polarity and transient overvoltages |
Typical Laser Lifetime (Hours) | - 75000 |
Feature: Remote Teach | - Yes |
Feature: Timing (Hold/Delay) | - No |
Feature: Chemical Resistant | - No |
Feature: Quick Disconnect | - No |
Common Ethernet Protocol | - No |
IO Link | - No |
PROFINET | - No |
RS-232 | - No |
RS-422 | - No |
RS-485 | - No |
SSI | - No |
Wireless | - No |
1-wire Serial Interface | - No |
Profibus | - No |
Product options for LT3PULV
Product tips for LT3PULV
Product announcements for LT3PULV
Product documents for LT3PULV
- LT3 SERIES CABLE/PIGTAIL | |
- LT3 SERIES CABLE/PIGTAIL | |
- LT3 SERIES CABLE/PIGTAIL | |
- LT3 SERIES CABLE/PIGTAIL | |
- LT3 Series with Class 1 Laser, Analog | |
- DoC for LT3 |