Product specifications for BLM460SHP-100AS
The BLM460SHP-100AS specifies: The BLM Series features a a compact, high-power and high-efficiency brushless DC motor. The entire motor structure features our latest brushless DC motor technology and has been innovated in pursuit of the optimal performance., *Connection Cable Required.,
Motor Type | - Brushless DC Motor |
Motor Frame Size | - 3.15 in., 80 mm |
Output Power | - 60 W (1/12 HP) |
Power Input | - AC |
Shaft/Gear Type | - Parallel Shaft Gearhead |
Gear Ratio (X:1) | - 100 :1 |
Output Shaft Diameter | - 5/8 inch |
Rated Torque | - 141 lb-in, 16 N·m |
Electromagnetic Brake | - Not Equipped |
Variable Speed Range (r/min) | - 0.8 ~ 40 |
Permissible Load Inertia | - 34000 oz-in², *When instantaneous stop or instantaneous bi-directional operation is performed = 3000 oz-in², 6200 x 10-4 kg·m², *When instantaneous stop or instantaneous bi-directional operation is performed = 550 x 10-4 kg·m² |
Permissible Radial Load | - 0.39 in. from Shaft End = 101 lb, 0.79 in. from Shaft End = 123 lb, 10 mm from Shaft End = 450 N, 20 mm from Shaft End = 550 N |
Permissible Axial Load | - 22 lb, 100 N |
Components | - BLM460SHP-GFV [Motor] GFV4G100AS [Gearhead] |
RoHS Compliant | - These products do not contain substances that exceed the regulation values in the RoHS Directive. |
Safety Standards | - UL, CSA, CE |
CE Marking | - Low Voltage Directives, EMC Directives |
Insulation Resistance (Motor) | - 100 MΩ or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. |
Dielectric Strength (Motor) | - Sufficient to withstand 1.5 kVAC at 50 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity. |
Temperature Rise (Motor) | - The temperature rise of the windings is 90ºF (50ºC) and that of the case is 72ºF (40ºC) when measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity. |
Ambient Temperature Range | - Motor: 32ºF ~ 104ºF (0ºC ~ 40ºC), nonfreezing Driver: 32ºF ~ 122ºF (0ºC ~ 50ºC) |
Ambient Humidity | - 85% or less, noncondensing |
Altitude | - Up to 3300 ft (1000 m) above sea level. |
Operating Atmosphere | - No corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum or other special environment. |
Thermal Class | - CSA standards: 105 (A), EN standards: 120 (E), UL |
Degree of Protection | - Motor: IP66 |