Product Description
- Specifications
- Product Options
- Tech Tips
- Announcements
- Documents
Product specifications for BXS5120A-30FR
The BXS5120A-30FR specifies: This product has been discontinued, please contact your local sales office for more information.
Motor Type | - Brushless DC Motor |
Motor Frame Size | - 3.54 in., 90 mm |
Output Power | - 120 W (1/6 HP) |
Power Supply | - Single-Phase 100-120 VAC |
Frequency | - 50 Hz, 60 Hz |
Rated Input Current | - 3.7 A |
Shaft/Gear Type | - Hollow Shaft Flat Gearhead |
Gear Ratio (X:1) | - 30 :1 |
Output Shaft Diameter | - 20 mm |
Rated Torque | - 90 lb-in, 10.2 N·m |
Electromagnetic Brake | - Not Equipped |
Variable Speed Range (r/min) | - Digital setting: 0.07 ~ 133 r/min (2000:1) Analog setting: 1 ~ 133 r/min (133:1) |
Permissible Load Inertia | - 8800 oz-in², *When instantaneous stop or instantaneous bi-directional operation is performed = 4900 oz-in², 1600 x 10-4 kg·m², *When instantaneous stop or instantaneous bi-directional operation is performed = 900 x 10-4 kg·m² |
Permissible Overhung Load | - 0.39 in. from Shaft End = 330 0.79 in. from Shaft End = 280 lb, 10 mm from Shaft End = 1500 20 mm from Shaft End = 1280 N |
Permissible Thrust Load | - 112 lb, 500 N |
Max. Extension Length (m) | - Motor and driver distance: 99.7 ft. (30.4 m) |
Components | - BXM5120-GFS [Motor], BXSD120-A [Driver], GFS5G30FR [Gearhead] |
RoHS Compliant | - These products do not contain substances that exceed the regulation values in the RoHS Directive. |
Safety Standards | - UL, CSA, CE |
CE Marking | - Low Voltage Directives, EMC Directives |
Insulation Resistance (Motor) | - 100 MΩ or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity (except for encoder). |
Insulation Resistance (Driver) | - 100 M Ω or more when 500 VDC megger is applied between the power supply input terminal and the case, and between the power supply input terminal and the I/O terminal after continuous operation under normal ambient temperature and humidity. |
Dielectric Strength (Motor) | - Sufficient to withstand 1.5 kVAC at 50 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity (except for encoder). |
Dielectric Strength (Driver) | - Sufficient to withstand 1.5 kVAC, 50 Hz applied between case and power supply input for 1 min. and 1.5 kVAC, 50 Hz applied between power supply input and the I/O terminal for 1 min. after continuous operation under normal ambient temperature and humidity. |
Temperature Rise (Motor) | - Temperature rise of the windings is 50ºC (90ºF) max. and that of the case surface is 40ºC (72ºF) max, measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity. |
Temperature Rise (Driver) | - Temperature rise of the heat sink is 50ºC (90ºF) max. measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity. |
Ambient Temperature Range | - 32ºF ~ 122ºF (0ºC ~ 50ºC), nonfreezing |
Ambient Humidity | - 85% max. (non-condensing) |
Operating Atmosphere | - No corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments. |
Altitude | - Max of 10000 ft. (3000 m) above sea level |
Insulation Class | - UL/CSA Standards: 105 (A), EN Standards: 120 (E) |
Degree of Protection | - IP54 (excluding connectors) [Motor] IP20 [Driver] |
Product options for BXS5120A-30FR
Product tips for BXS5120A-30FR
Product announcements for BXS5120A-30FR
Product documents for BXS5120A-30FR
- Product Catalog | |
- BX II Series User Manual | |
- OPX-2A Operating Manual | |
- 3D CAD (Motor) (*.step) | |
- 3D CAD (Driver) (*.step) |