Product specifications for AR46ACD-H100-3
The AR46ACD-H100-3 specifies: This package part number has been discontinued. We are now offering these as component products., Please contact your local sales office for updated part numbers.
Product Line | - Oriental Motor® | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Frame Size | - 1.65 in, 42 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Motor Length | - 3.96 in., 100.5 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Speed-Torque Characteristics | - Holding Torque Holding Torque | - 704 oz-in, 5 N·m | Type | - Continuous Duty | Shaft/Gear Type | - Harmonic Gear | Gear Ratio (X:1) | - 100 :1 | Feedback Device (Motor) | - Resolver | Shaft | - Single | Electromagnetic Brake | - Not Equipped | Power Supply | - Single-Phase 200-230 VAC | Resolution (Resolution Setting: 1000 P/R) | - 0.0036 °/Pulse | Permissible Speed Range (r/min) | - 0 ~ 35 | Rotor Inertia | - 0.41 oz-in², 75x10-7 kg·m² | Lost Motion | - 1.5 arc min (max.) | Control Power Supply | - 24 VDC ± 5%, 0.5A | RoHS Compliant | - Yes | Safety Standards | - UL, CE | CE Marking | - Low Voltage Directives, EMC Directives | Components | - ARD-CD [Driver], ARM46AC-H100 [Motor] | Insulation Class | - [Motor] Class B [130ºC (266ºF)] | Insulation Resistance (Motor) | - 100 MΩ or more when 500 VDC megger is applied between the following places: | Case - Motor and sensor windings Insulation Resistance (Driver) | - 100 MΩ or more when 500 VDC megger is applied between the following places: | PE terminal - Power supply terminal Signal I/O terminal - Power supply terminal Dielectric Strength (Motor) | - Sufficient to withstand the following for 1 minute: | Case - Motor and sensor windings 1.5 kVAC 50 Hz or 60 Hz Dielectric Strength (Driver) | - Sufficient to withstand the following for 1 minute: | PE terminal - Power supply terminal 1.8 kVAC 50 Hz or 60 Hz Signal I/O terminal - Power supply terminal 1.9 kVAC 50 Hz or 60 Hz Ambient Temperature (Motor) | - 0 ~ 40ºC (32 ~ 104ºF) (non-freezing) | (when a heat sink of a capacity at least equivalent to an aluminum plate with a size of 9.84 x 9.84 in., 0.24 in. thick is installed.) Ambient Temperature (Driver) | - 0 ~ 55ºC (32 ~ 131ºF) (non-freezing) | (when a heat sink of a capacity at least equivalent to an aluminum plate with a size of 7.87 x 7.87 in., 0.08 in. thick is installed.) Ambient Humidity | - 85% or less (Non-condensing) | Operating Atmosphere | - No corrosive gases, dust water or oil | Degree of Protection | - [Motor] IP65 (excluding the mounting surface and connector) | [Driver] IP10 Stop Position Accuracy | - ±4 arc minutes (±0.067º) | Shaft Runout | - 0.05 mm (0.002 in.) T.I.R. | Concentricity | - 0.075 mm (0.003 in.) T.I.R. | Perpendicularity | - 0.075 mm (0.003 in.) T.I.R. | Radial Load | - 0 in. from Shaft End = 40 lb, 0.2 in. from Shaft End = 49 lb, 0.39 in. from Shaft End = 60 lb, 0.59 in. from Shaft End = 81 lb, 0.79 in. from Shaft End = 114 lb, 0 mm from Shaft End = 180 N, 5 mm from Shaft End = 220 N, 10 mm from Shaft End = 270 N, 15 mm from Shaft End = 360 N, 20 mm from Shaft End = 510 N | Axial Load | - 49 lb, 220 N | Driver Type | - Built-in Controller (Stored Data Type) | |
Product options for AR46ACD-H100-3
Product tips for AR46ACD-H100-3
Product announcements for AR46ACD-H100-3
Product documents for AR46ACD-H100-3
- Connection and Operation | |
- Product Catalog | |
- AR Series User Manual | |
- Motor CAD 2D (DXF) | |
- Driver CAD 2D (DXF) | |
- 3D CAD (*.step) |