Product specifications for 4TK10GN-CW2E / 4GN90SA
The 4TK10GN-CW2E / 4GN90SA specifies: Torque motors have a high starting torque and torque that decreases as speed increases and varies with the voltage applied to the motor, allowing easy speed control simply by changing the voltage of the power supply.,
Product Line | - Oriental Motor® |
Motor Type | - Torque |
Frame Size | - 3.15 in, 80 mm |
Output Power | - 10 W (1/75 HP) |
Voltage (VAC) | - Single-Phase 220/230 VAC |
Frequency (Hz) | - 60, 50 |
Current | - 0.39 A [230 VAC, 50 Hz], 0.40 A [230 VAC, 60 Hz], 0.41 A [220 VAC, 50 Hz], 0.45 A [220 VAC, 60 Hz] |
Shaft/Gear Type | - Parallel Shaft Gearhead |
Gear Ratio (X:1) | - 90 :1 |
Output Shaft | - Imperial |
Output Shaft Diameter | - 3/8 in. |
Starting Torque | - 70 lb-in , 8 N·m |
Torque at Max Output | - 68.31 lb-in , 7.72 N·m |
Speed at Max Output (rpm) | - 10 [60 Hz], 8 [50 Hz] |
Permissible Overhung Load | - 0.39 in. from Shaft End = 45 lb, 0.79 in. from Shaft End = 67 lb, 10 mm from Shaft End = 200 N, 20 mm from Shaft End = 300 N |
Permissible Thrust Load | - 11.20 lb, 50 N |
RoHS Compliant | - Yes |
Safety Standards | - UL, CSA, CCC, CE |
CE Marking | - Low Voltage Directives |
Insulation Resistance | - 100 MΩ or more when 500 VDC megger is applied between the windings and the frame after rated motor operation under normal ambient temperature and humidity. |
Dielectric Strength | - Sufficient to withstand 1.5 kV at 50Hz or 60 Hz applied between the windings and the frame for 1 minute after rated motor operation under normal ambient temperature and humidity. |
Temperature Rise | - Temperature rise of windings are 80ºC (176ºF) or less measured by the resistance change method after rated motor operation under normal ambient temperature and humidity. |
Insulation Class | - Class B (266°F [130°C]) |
Overheat Protection | - Built-in thermal protector (Automatic return type). Operating temperature, open: 266°F ± 9°F (130°C ± 5°C) close: 179.6°F ± 27°F (82°C ± 15°C) |
Ambient Temperature Range | - 14°F ~ 104°F (-10°C ~ 40°C) (nonfreezing) |
Ambient Humidity | - 85% or less (noncondensing) |
Degree of Protection | - IP20 |
Product options for 4TK10GN-CW2E / 4GN90SA
Product tips for 4TK10GN-CW2E / 4GN90SA
Product announcements for 4TK10GN-CW2E / 4GN90SA
Product documents for 4TK10GN-CW2E / 4GN90SA
- Common Specifications | |
- Product Catalog | |
- GN/GE/GU Gear Operating Manual | |
- Torque Motor Operating Manual | |
- Motor CAD 2D (DXF) | |
- 3D CAD (Motor) (*.step) |