Product Description
- Specifications
- Product Options
- Tech Tips
- Announcements
- Documents
Product specifications for 2IK6GN-SW2 / 2GN100SA
The 2IK6GN-SW2 / 2GN100SA specifies: Induction motors are optimal for uni-directional continuous operation such as a conveyor system., Optimal for uni-directional continuous operation, Conform to safety standards and global power supply voltages,
Product Line | - Oriental Motor® |
Motor Type | - Induction |
Frame Size | - 2.36 in, 60 mm |
Output Power | - 6 W (1/125 HP) |
Voltage (VAC) | - Three-Phase 200/220/230 VAC |
Frequency (Hz) | - 60, 50 |
Current | - 0.072 A [200 VAC, 60 Hz], 0.076 A [220 VAC, 60 Hz], 0.079 A [230 VAC, 60 Hz], 0.081 A [200 VAC, 50 Hz] |
Shaft/Gear Type | - Parallel Shaft Gearhead |
Gear Ratio (X:1) | - 100 :1 |
Output Shaft | - Imperial |
Output Shaft Diameter | - 5/16 in. |
Type | - Lead Wire |
Electromagnetic Brake | - Not Equipped |
Rated Torque | - 23 lb-in [60 Hz] , 26 lb-in [50 Hz] , 2.7 N·m [60 Hz] , 3 N·m [50 Hz] |
Rated Speed (rpm) | - 15 [200 VAC, 50 Hz], 18 [60 Hz] |
Permissible Load Inertia | - 850 oz-in², 155 x 10-4 kg·m² |
Permissible Overhung Load | - 0.39 in. from Shaft End = 27 lb, 0.79 in. from Shaft End = 40 lb, 10 mm from Shaft End = 120 N, 20 mm from Shaft End = 180 N |
Permissible Thrust Load | - 6.7 lb, 30 N |
RoHS Compliant | - Yes |
Safety Standards | - UL, CSA, CCC, EN, CE |
CE Marking | - Low Voltage Directives |
Insulation Resistance | - 100 MΩ or more when 500 VDC megger is applied between the windings and the frame after rated motor operation under normal ambient temperature and humidity. |
Dielectric Strength | - Sufficient to withstand 1.5 kV at 50 Hz or 60 Hz applied between the windings and the frame for 1 minute after rated motor operation under normal ambient temperature and humidity. |
Temperature Rise | - Temperature rise of windings are 126ºF (70ºC) or less measured by the resistance change method after rated motor operation with connection to gearhead. |
Insulation Class | - Class B (266ºF [130ºC]) |
Overheat Protection | - Impedance protection |
Ambient Temperature Range | - Three-phase 200 VAC: 14ºF ~ 122ºF (-10ºC ~ 50ºC) (nonfreezing), Other voltage: 14ºF ~ 104ºF (-10ºC ~ 40ºC) (nonfreezing) |
Ambient Humidity | - 85% maximum (noncondensing) |
Degree of Protection | - IP20 |
Product options for 2IK6GN-SW2 / 2GN100SA
Product tips for 2IK6GN-SW2 / 2GN100SA
Product announcements for 2IK6GN-SW2 / 2GN100SA
Product documents for 2IK6GN-SW2 / 2GN100SA
- Induction Motor Catalog | |
- Common Specifications | |
- GN/GE/GU Gear Operating Manual | |
- World K Series Operating Manual | |
- 3D CAD (Motor) (*.step) |