Product Description
- Specifications
- Product Options
- Tech Tips
- Announcements
- Documents
Product specifications for SCM540KUAM-5H30B / DSCD40UAM
The SCM540KUAM-5H30B / DSCD40UAM specifies: The DSC Series features AC motors and speed controllers that utilized Oriental Motor's exclusive technology., Closed Loop Control for High Reliability, Easy Installation and Simple Data Setting, Compact Motor and Controller (with Capacitor),
Product Line | - Oriental Motor® |
Motor Type | - AC Motor |
Motor | - Induction |
Frame Size | - 3.54 in, 90 mm |
Output Power | - 40 W (1/19 HP) |
Power Supply | - Single-Phase 110/115 VAC |
Frequency (Hz) | - 60 |
Current | - 1.1 A |
Control Power Source | - 24 VDC ±10% 0.15 A or more |
Shaft/Gear Type | - Right-Angle Hollow Shaft (Stainless Steel) Gearhead |
Gear Ratio (X:1) | - 30 :1 |
Output Shaft Diameter | - 15 mm |
Electromagnetic Brake | - Equipped |
Permissible Torque | - [Deceleration Control: ON] 18.5 lb-in [Deceleration Control: OFF] 42 lb-in , [Deceleration Control: ON] 2.1 N·m [Deceleration Control: OFF] 4.8 N·m |
Variable Speed Range (r/min) | - [Deceleration Control: ON] 10 ~ 53 [Deceleration Control: OFF] 3 ~ 53 |
Permissible Load Inertia | - 9800 oz-in², 1800 x 10-4 kg·m² |
Permissible Overhung Load | - 0.39 in. from Installation Surface = 200 lb, 0.79 in. from Installation Surface = 181 lb, 10 mm from Installation Surface = 923 N, 20 mm from Installation Surface = 806 N |
Permissible Thrust Load | - 55 lb, 245 N |
RoHS Compliant | - These products do not contain substances that exceed the regulation values in the RoHS Directive. |
Safety Standards | - c-UL, CCC, CE |
CE Marking | - Low Voltage Directives, EMC Directive |
Insulation Resistance | - [Controller] 100 MΩ or more when measured by a 500 VDC between the main circuit terminal and the control circuit terminal, between the main circuit terminal and the case and between the main circuit terminal and FG after continuous operation under normal ambient temperature and humidity., [Motor] 100 MΩ or more when 500 VDC megger is applied between the windings and the case after rated operation under normal ambient temperature and humidity. |
Dielectric Strength | - [Controller] Sufficient to withstand 1.9 kVAC at 50 Hz or 60 Hz applied between the main circuit terminal and the control circuit terminal, and between the main circuit terminal and the case, and 1.5 kVAC at 50 Hz or 60 Hz applied between the main circuit terminal and FG for 1 minute after continuous operation under normal ambient temperature and humidity., [Motor] Sufficient to withstand 1.5 kVAC at 50 Hz or 60 Hz applied between the windings and the case for 1 minute after rated operation under normal ambient temperature and humidity. |
Temperature Rise | - A gearhead or equivalent heat sink is connected to the motor and the winding temperature rise is measured at 176ºF (80ºC) or less using the resistance change method after rated operation with no load under normal ambient temperature and humidity. |
Overheat Protection Device | - Built-in Thermal Protector (automatic return type) |
Ambient Temperature Range | - [Controller] 32ºF ~ 122ºF (0ºC ~ 50ºC), [Motor] 14ºF ~ 104ºF (-10ºC ~ 40ºC) (nonfreezing) |
Ambient Humidity | - 85% max. (non-condensing) |
Altitude | - Max. of 1000 m (3300 ft.) above sea level |
Thermal Class | - 130 (B) |
Degree of Protection | - IP20 |
Product options for SCM540KUAM-5H30B / DSCD40UAM
Product tips for SCM540KUAM-5H30B / DSCD40UAM
Product announcements for SCM540KUAM-5H30B / DSCD40UAM
Product documents for SCM540KUAM-5H30B / DSCD40UAM
- SCM Motor Operating Manual | |
- Driver Operating Manual | |
- 3D CAD (Motor / Rack and Pinion) (*.step) | |
- 3D CAD (Driver) (*.step) |