Product Description
- Specifications
- Product Options
- Tech Tips
- Announcements
- Documents
Product specifications for DGM130R-ARAC / ARD-CD
The DGM130R-ARAC / ARD-CD specifies: The DGII Series uses a highly rigid hollow rotary table with a efficient and energy saving AlphaStep AR Series closed loop motor and driver package allowing for highly accurate positioning of larger inertia loads. The built-in controller (stored data) allows for easy networking and simplified multi-axis control., Controller connection options: 1: I/O, 2: Modbus (RTU/RS-485) or 3: FA Network (network converter), Large-Diameter, Hollow Output Table, Direct Coupling, Accurate Positioning, Shorter Positioning Time, Easy Home Operation, Designed for Continuous Operation, *Connection cables required (sold separately)., ,
Frame Size | - 5.12 in, 130 mm |
Power Supply | - Single-Phase 200-240 VAC |
Shaft | - Single |
Electromagnetic Brake | - Not Equipped |
Output Table Supporting Bearing | - Cross-Roller Bearing |
Permissible Torque | - 106 lb-in, 12 N·m |
Inertia | - 150620x10-7 kg·m², 820 oz-in² |
Permissible Speed (r/min) | - 200 |
Gear Ratio (X:1) | - 18 :1 |
Max. Holding Torque | - 106 lb-in, 12 N·m |
Resolution (Resolution Setting: 1000 P/R) | - 18000 P/R (0.02º) |
Frequency | - 50/60 Hz |
Input Current | - 2.3 A |
Control Power Supply | - 24 VDC ±5% 0.5 A |
Repetitive Positioning Accuracy (arc sec) | - ±15 arc sec (±0.004º) |
Lost Motion | - 2 arc minute (0.033°) |
Angular Transmission Accuracy | - 3 arc minute (0.05º) |
Permissible Thrust Load | - 2000 N, 450 lb |
Permissible Moment Load | - 50 N·m, 440 lb-in |
Runout of Output Table Surface | - 0.015 mm, 0.0006 in. |
Runout of Output Table Inner (Outer) Diameter | - 0.015 mm, 0.0006 in. |
Parallelism of Output Table | - 0.03 mm, 0.0012 in. |
Degree of Protection | - [Actuator] IP40 (IP20 for motor connector), [Driver] IP10 |
Insulation Class | - 130 (B) |
Insulation Resistance (Actuator) | - 100 MΩ minimum when measured by a 500 VDC megger between the Case - Motor and Sensor Windings |
Insulation Resistance (Driver) | - 100 M Ω minimum when measured by a 500 VDC megger between the PE Terminal - Power Input Terminal |
Dielectric Strength (Actuator) | - No abnormality is found with the following application for 1 minute: Case - Motor and Sensor Windings 1.5 kV, 50 Hz or 60 Hz |
Dielectric Strength (Driver) | - No abnormality is found with the following application for 1 minute: PE Terminal - Power Supply Terminal 1.8 kV, 50 Hz or 60 Hz Signal I/O Terminal - Power Supply Terminal 1.9 kV, 50 Hz or 60 Hz |
Ambient Temperature (Actuator) | - 0 ~ +50ºC (+32 ~ 122ºF)(non-freezing) 0 ~ +40ºC (+32 ~ 104ºF)(non-freezing) when home-sensor set (accessory is attached) |
Ambient Temperature (Driver) | - 0 ~ +55ºC (+32 ~ 131ºF)(non-freezing) |
Ambient Humidity | - 85% max. (non-condensing) |
Operating Atmosphere | - Use in an area without corrosive gases and dust. The product should not be exposed to water, oil or other liquids. |
Safety Standards | - CE |
RoHS Compliant | - Yes |
Components | - ARD-CD (Driver), DGM130R-ARAC (Actuator) |
Product options for DGM130R-ARAC / ARD-CD
Product tips for DGM130R-ARAC / ARD-CD
Product announcements for DGM130R-ARAC / ARD-CD
Product documents for DGM130R-ARAC / ARD-CD
- DGII Series Operating Manual | |
- AR Series User Manual | |
- Motorized Actuator Function Setting | |
- Driver CAD 2D (DXF) | |
- Actuator CAD (2D DXF) | |
- 3D CAD (*.step) |