Product Description
- Specifications
- Product Options
- Tech Tips
- Announcements
- Documents
Product specifications for BLM5120HP-200S / BMUD120-A2
The BLM5120HP-200S / BMUD120-A2 specifies: The BMU Series features a compact, high-power and high-efficiency brushless DC motor (BLDC motor) and is combined with an easy to use, easy to set speed controller. The entire motor structure features our latest brushless DC motor technology and has been innovated in pursuit of the optimal performance., High-efficiency motor, Wide Speed Control Range, Easy wiring and set up, Expanded functions, IP66 rated motor, *Connection Cable Required.,
Motor Type | - Brushless DC Motor |
Motor Frame Size | - 3.54 in., 90 mm |
Output Power | - 120 W (1/6 HP) |
Power Supply | - Single-Phase 100-120 VAC |
Shaft/Gear Type | - Parallel Shaft Gearhead (Stainless Steel Shaft) |
Gear Ratio (X:1) | - 200 :1 |
Output Shaft Diameter | - 18 mm |
Rated Torque | - 260 lb-in, 30 N·m |
Electromagnetic Brake | - Not Equipped |
Variable Speed Range (r/min) | - 0.4 ~ 20 |
Permissible Load Inertia | - 137000 oz-in², *When instantaneous stop or instantaneous bi-directional operation is performed = 13700 oz-in², 25000 x 10-4 kg·m², *When instantaneous stop or instantaneous bi-directional operation is performed = 2500 x 10-4 kg·m² |
Permissible Radial Load | - 0.39 in. from Shaft End = 112 0.79 in. from Shaft End = 146 lb, 10 mm from Shaft End = 500 20 mm from Shaft End = 650 N |
Permissible Axial Load | - 33 lb, 150 N |
Max. Extension Length (m) | - 10.50 |
Components | - BLM5120HP-200S (Motor) BMUD120-A2 (Driver) |
RoHS Compliant | - These products do not contain substances that exceed the regulation values in the RoHS Directive. |
Safety Standards | - UL, CSA, CE |
CE Marking | - Low Voltage Directives, EMC Directives |
Insulation Resistance (Motor) | - 100 MΩ or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. |
Insulation Resistance (Driver) | - 100 MΩ or more when a 500 VDC megger is applied between the power supply terminal and the protective earth terminal and between the power supply terminal and the I/O signal terminal after continuous operation under normal ambient temperature and humidity. |
Dielectric Strength (Motor) | - Sufficient to withstand 1.5 kVAC at 50 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity. |
Dielectric Strength (Driver) | - No abnormality is judged even with application of 1.5 VAC at 50 Hz between the power supply terminal and the protective earth terminal and with application of 1.5 kVAC at 50 Hz between the power supply terminal and the I/O terminal for 1 minute after continuous operation under normal ambient temperature and humidity. |
Temperature Rise (Motor) | - The maximum temperature rise of the windings is 90ºF (50ºC) and that of the case is 72ºF (40ºC) when measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity. |
Temperature Rise (Driver) | - Temperature rise of the heat sink is 90ºF (50ºC) or less measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity. |
Ambient Temperature Range | - 32ºF ~ 104ºF (0ºC ~ 40ºC), nonfreezing |
Ambient Humidity | - 85% or less, noncondensing |
Altitude | - Up to 3300 ft (1000 m) above sea level. |
Operating Atmosphere | - No corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum or other special environment. |
Thermal Class | - CSA standards: 105 (A), EN standards: 120 (E), UL |
Degree of Protection | - [Motor] IP66 [Driver] IP20 |
Product options for BLM5120HP-200S / BMUD120-A2
Product tips for BLM5120HP-200S / BMUD120-A2
Product announcements for BLM5120HP-200S / BMUD120-A2
Product documents for BLM5120HP-200S / BMUD120-A2
- 3D CAD (Motor) (*.stp) | |
- 3D CAD (Driver) (*.step) | |
- Brushless DC Motor Operating Manual | |
- BMU Series Operating Manual |