Product specifications for BLV510K100S-1
The BLV510K100S-1 specifies: The BLV Series brushless DC motor (BLDC motor) speed control system offers high performance and simple operation from a compact motor and driver., Slim, Yet Powerful Design, Wide Speed Range, DC Input, Battery drive function, Communication through I/O or RS-485 available, 3.3 ft. (1 m) Cable Included,
Motor Type | - Brushless DC Motor |
Motor Frame Size | - 3.54 in., 90 mm |
Output Power | - 100 W (1/8 HP) |
Power Supply | - 24 VDC |
Shaft/Gear Type | - Parallel Shaft Gearhead |
Gear Ratio (X:1) | - 100 :1 |
Output Shaft Diameter | - 18 mm |
Rated Torque | - 265 lb-in, 30 N·m |
Electromagnetic Brake | - Not Equipped |
Cable Length (Included) | - 1 m (3.3 ft.) |
Variable Speed Range (r/min) | - 1 ~ 30 |
Permissible Load Inertia | - 66000 oz-in², *When instantaneous stop or instantaneous bi-directional operation is performed = 13700 oz-in², 12000 x 10-4 kg·m², *When instantaneous stop or instantaneous bi-directional operation is performed = 2500 x 10-4 kg·m² |
Permissible Overhung Load | - 0.39 in. from Shaft End = 112 lb, 0.79 in. from Shaft End = 146 lb, 10 mm from Shaft End = 500 N, 20 mm from Shaft End = 650 N |
Permissible Thrust Load | - 33 lb, 150 N |
Type | - Cable |
Speed Control Method (Select one of the following) | - Internal potentiometer, External DC voltage, External potentiometer (20kΩ, 1/4W) |
Number of Speed Settings | - 2 Standard / 8 with MEXE02 Softwre or OPX-2A Controller |
Instantaneous Stop | - Yes |
Multi-Axes Control | - Yes |
Alarm Output | - Yes |
Power Input | - DC |
Max. Extension Length (m) | - 1.5 |
Components | - BLVM510K-GFS [Motor] GFS5G100 [Gearhead] BLVD10KM [Driver] CC01BLV3 [Cable] |
RoHS Compliant | - Yes |
Safety Standards | - CE |
CE Marking | - EMC Directives |
Insulation Class | - [Motor] EN: Class E [120ºC (248ºF)] |
Insulation Resistance (Motor) | - 100 MΩ or more when 500 VDC megger is applied between the windings and the frame after continuous operation under normal ambient temperature and humidity. |
Insulation Resistance (Driver) | - 100 M Ω or more when 500 VDC megger is applied between the power supply terminal and heat radiation plate after continuous operation under normal ambient temperature and humidity. |
Dielectric Strength (Motor) | - Sufficient to withstand 0.5 kVAC at 50Hz applied between the windings and the frame for 1 minute after continuous operation under normal ambient temperature and humidity. |
Dielectric Strength (Driver) | - Sufficient to withstand 0.5 kVAC at 50Hz applied between the power supply terminal and the heat radiation plate for 1 minute after continuous operation under normal ambient temperature and humidity. |
Ambient Temperature Range | - 0ºC ~ +40ºC (+32ºF ~ +104ºF) (nonfreezing) |
Ambient Humidity | - 85% max. (noncondensing) |
Operating Atmosphere | - No corrosive gases or dust.Cannot be used in radioactive area, magnetic field, vacuum or other special environment. |
Degree of Protection | - [Driver] IP20, [Motor] IP65 (excluding connector) |
Degree of Protection (Motor) | - IP65 |
Product options for BLV510K100S-1
Product tips for BLV510K100S-1
Product announcements for BLV510K100S-1
Product documents for BLV510K100S-1
- BLV Series Operating Manual | |
- BLV Series User Manual | |
- BLV Series RS-485 User Manual | |
- BLV Series Network Converter Manual | |
- 3D CAD (Driver) (*.step) | |
- 3D CAD (Motor) (*.step) |